Surplus Hitachi H-25 Gas Turbine Generator Sets (2) | 32.7 MW (ISO) | BRUSH 36,334 kVA, 13.8 kV, 60 Hz Item No. CTG-GTN-0112-01 & 02 CTG Power Systems Intnl., LLC offers two low-hour Hitachi H-25 heavy-duty industrial gas turbine generator sets, each rated 32,700 kW (ISO) in open simple-cycle configuration on natural gas, with BRUSH 36,334 kVA / 13.8 kV / 60 Hz synchronous generators. Manufactured 2012, commissioned 2014, approximately 21,000 recorded operating hours each. Surplus condition, located in India. Available immediately, subject to prior sale.
CTG-GTN-0112_Hitachi_H-25_Gas_Turbine_Sales_Sheet.pdf
Item No. CTG-GTN-0112-01 & CTG-GTN-0112-02 | Location: India | Condition: Surplus (used, as removed from service)
CTG Power Systems Intnl., LLC offers for sale two (2) Hitachi H-25 gas turbine generator sets removed from a decommissioned host plant. Each unit is rated 32,700 kW (ISO) in open simple-cycle configuration, firing natural gas, and is paired with a BRUSH 36,334 kVA, 13.8 kV, 60 Hz, 0.90 PF synchronous generator. Combined nameplate output for the pair is 65.4 MW (ISO).
Both units were manufactured in 2012, commissioned in 2014, and operated on natural gas until the host plant was shut down in an orderly manner in 2023. Recorded operating hours are approximately 21,000 per unit, well short of the first major inspection interval on a typical natural-gas duty cycle.
The H-25 is a single-shaft, 17-stage axial-compressor machine deployed worldwide in industrial cogeneration and simple-cycle peaking service. The product line is now supported by Mitsubishi Power. These are 60 Hz machines, which matters for U.S. deployment where most available pre-owned heavy-frame turbines are 50 Hz.
Each set is complete with generator, BRUSH brushless exciter, CACA-3 air-cooled generator cooler (3 motors), and a Hitachi excitation control panel with automatic voltage regulator (AVR) and automatic synchronizer (ASS). Turbine control system, package auxiliaries, lube-oil system, starting system, inlet air filtration, and exhaust components are included as installed at the host site, with inventory to be confirmed on inspection.
The units suit behind-the-meter, bridge, and baseload applications needing 30 to 65 MW of dispatchable natural-gas generation. The 554 °C exhaust temperature also supports heat recovery in combined-cycle or cogeneration configurations. Rated at 25 ppm NOx (dry, corrected to 16% O₂), the turbines support permitting in many U.S. jurisdictions under 40 CFR Part 60 Subpart KKKK, as-is or with SCR where a lower limit applies.
Highlights
Gas Turbine Specifications (per unit)
Generator Specifications (per unit)
Rated output and cycle data are as recorded on the manufacturer's data sheet at the original site and design conditions. Site rating at the purchaser's location depends on ambient temperature, elevation, and fuel specification and will be confirmed in CTG's formal proposal.
Scope of Supply (per unit, to be confirmed in formal proposal)
Not included unless separately quoted: dismantling, packing, and transport; site civil works and foundations; step-up transformer, switchgear, and interconnection; exhaust after-treatment (SCR / CO catalyst); reconditioning or major inspection prior to shipment; installation, commissioning, training, and long-term service. CTG can quote any of these as part of a complete package, including substation transformers and switchgear from CTG's core product lines.
Condition and Inspection
The equipment is available for physical inspection by the purchaser or its appointed engineer, including visual inspection, records review, and, subject to site conditions, borescope inspection of the hot-gas path. Maintenance history, inspection reports, nameplate images, and additional photographs are available under non-disclosure agreement. Sold as-inspected, as-recorded. CTG makes no representation as to remaining life beyond the manufacturer's published inspection intervals and the recorded operating history; the purchaser is responsible for its own technical evaluation.
Terms
Request the formal proposal, arrange an inspection, or ask for records under NDA. Reference Item No. CTG-GTN-0112-01 & 02.