One (1) Used Centaur 50 60 Hz. 13.8 kV Gas Turbine Generator Package 23,000 Hrs. Dual Fuel SoLoNOx Combustion System, 25/96 ppmv NOx



Learn More


One used Centaur 50 built in 2015 with 23,000 hours. Voltage is 13.8 kV.

SCOPE OF SUPPLY

Centaur 50 GAS TURBINE PACKAGE
• Gas turbine
• Reduction-drive gearbox
• Generator
• Start system
• Fuel system
• Lubricating oil system
• Turbotronic 4 Control System
• Air inlet system
• Exhaust system
• Onskid electrical wiring
• Skid with drip pans
• Piping and manifolds
• Package enclosure with:
• Ventilation system
• Fire detection and suppression system
• Combustible gas detection

Centaur 50 GAS TURBINE ENGINE
• SoLoNOx Combustion System, 25/96 ppmv NOx, Dual Fuel
• Inlet Orientation, Up
• Exhaust Orientation, Axial

REDUCTION-DRIVE GEARBOX

• 1800 RPM 60 Hz

GENERATOR AND ASSOCIATED EQUIPMENT
• Kato
• 13800 V

START SYSTEM
• Direct-drive AC start

FUEL SYSTEM
• Natural Gas

LUBRICATION SYSTEM
• Oil tank
• Oil tank heater

TURBOTRONIC 4 CONTROL SYSTEM  /ONSKID CONTROL SYSTEM
• ControlLogix controller (Allen-Bradley)
• RSLogix 5000 programming software (Rockwell Automation)
• 1794 Flex I/O input/output modules (Allen-Bradley)
• Combination generator control module (Allen-Bradley/Basler Electric)
• Vibration monitoring system
• ControlNet network (ControlNet International)
• TT4000S onskid local operator interface (Solar Turbines)
• Fire and gas monitoring and control system (Det-tronics)
• Independent backup shutdown system (Solar Turbines)
• Auxiliary Control Console for Offskid Control Interface
• Engine Performance Map Display
• Ethernet Network Supervisory Interface
• Control Screen Engineering Units in English
• Control Screen Language in English

GENERATOR CONTROL AND MONITORING
• Automatic voltage regulation (AVR) - A constant generator output voltage is maintained
• Power factor (PF) control - A constant power factor is maintained when operating in parallel with a large power source
• Reactive power control - A constant reactive load is maintained when operating in parallel with a large power
source
• Generator Metering Panel
• Generator Vibration Monitoring System with 2X and 2Y Proximity Probes, 4 Channels
• Generator Key phasor

ENCLOSURE
• Complete Package Enclosure
• Dual Fan Ventilation System
• AC Lighting
• Equipment Handling Kit, Quantity 1
• Fire and Gas Detection System
• CO2 Fire Suppression System
• CO2 Isolation Valves, Pressure Switches, and Software
• Fire Cylinder Cabinets
• Weather / Sound Proofing
• Inlet / Exhaust Ventilation Silencers
• Pressurization System
• Access Doors