New Listing
New Listing
New Listing
CTG Power Systems International LLC is offering for immediate sale and delivery One (1) Used Decommissioned General Electric Frame 7EA Gas Turbine Generator Set consisting of the following basic scope of supply: • One (1) GE Model 7A1PEA381 Gas Turbine - Mfg: 1997 • Duel Fuel, Base Rated 81,730 KW / Peak Rated 89,490 KW • Steam Injected Combustion with Inlet Air-Cooled • Heat Rate at ISO:10,480 Btu/kWh • 60 Hz.
Download File>>>>>>CTG~GT2F-0418_One (1) GE Model 7A1PEA381 Gas Turbine Genset.pdf
CTG Power Systems International LLC is offering for immediate sale and delivery One (1) Used General Electric Frame 7EA Gas Turbine Generator Set consisting of the following basic scope of supply:
One (1) GE Model 7A1PEA381 Gas Turbine - Mfg: 1997
Duel Fuel, Base Rated 81,730 KW / Peak Rated 89,490 KW
Steam Injected Combustion with Inlet Air-Cooled
Heat Rate at ISO:10,480 Btu/kWh
Serial Number: 295600
RPM: 3600 rpm / CCW rotation
GE 800 hp Motor Starter, Model 8213825402 - 3570 RPM, Frame: 8211Z, 2300/4000V
Philadelphia Accessory Gear Box with Atomizing Air Compressor
Side Exhaust To HRSG
Worthington Natural Gas Compressor
Liquid Fuel Pump and Supply System
GE TEWAC Generator Rated 105,778 kva, 13800V, 3 Phase, 60 Hz., PF: 0.9 bearing Serial Number: 336X349, 4425 Amps, 300V Exciter Volts, Field Amps: 874. 3600 RPM
Frame 7A6
Mark IV Control System, EX2000 Exciter , MCC Room, Control Room
Enclosure: Outdoor Housing
History:
Unit Startup: 03/01/1992
Shutdown 08/2022
Total Hours: 61344
Total Starts: 5590
Major Inspection and Upgrade Performed: Year 2000
Year Last Overhaul: 2013
Hours Since Last Overhaul: Approx. 3000 Hours
Status: Still Installed in Place